Status > Graphic Status
Graphic Status

This feature is used to display a graphical status of a door controller, including the status of all its components (outputs, inputs, power supply status, communication status, etc.) represented by coloured shapes (circle, square, etc.).

•   An ellipse shape represents the controller

•   A circle represents a door

•   A square represents a relay

•   A rectangle represents an input. Rectangles may be horizontal (KT-200 and KT-300) or vertical (KT-100).

Viewing a Controller Status

1 - From the Gateway  drop-down list, select the gateway on which the controller to display is located. You may select “All gateways” to display all the controllers in the list.

2 - From the Controller drop-down list, select the controller for which you want to display the status.

Example with a KT-200 Controller

kt200GraphicalStatus.jpg

Example with a KT-400 Controller

Note: The displayed graphic depends on the type of the controller selected.

3 - To find out which items are represented by a coloured shape, move the mouse over a coloured shape. The item highlighted on the right-hand (in the list) identifies the component.

4 - Select a controller from the Controller list  drop-down list (right side of the window), double-click the item on which status is required.

•   Red —The component is “Supervised” and “in a trouble state”.

•   Green —The component is “Supervised” and “in normal condition”.

•   Yellow —The component is “Not Supervised” and “in a trouble state”.

•   Gray —The component is “Not Supervised” and “in normal condition”.

•   Blue —The relay is activated (by an event or an operator).

Note: If there’s more than one controller connection per gateway, the numbers between parentheses (xx) indicates the controller number and the following numbers (xx) indicate the component number.